5V, 12V, 24V Switching Power Supply is used to supply power to laser control card etc. Laser Machine Parts, this DC Switch Power Supply is very important laser accessories for Laser Cutting and Engraving Systems.
Protection: Over load, over voltage, short circuit
|
Model
Specification
|
S-50-5
|
S-50-12
|
S-50-15
|
S-50-24
|
|
DC output voltage
|
5V
|
12V
|
15V
|
24V
|
|
Output voltage error (Note2)
|
± 2%
|
± 1%
|
± 1%
|
± 1%
|
|
Rated output current
|
10A
|
4.2A
|
3.4A
|
2.1A
|
|
Output current rage
|
0-10A
|
0-4.2A
|
0-3.4A
|
0-2.1A
|
|
Wave and noise(Note3)
|
75mVp-p
|
100mVp-p
|
100mVp-p
|
100mVp-p
|
|
Inlet stability(Note4)
|
± 0.5%
|
± 0.5%
|
± 0.5%
|
± 0.5%
|
|
Load stability(Note5)
|
± 1%
|
± 0.5%
|
± 0.5%
|
± 0.5%
|
|
DC output power
|
50W
|
50.4W
|
50.4W
|
50.4W
|
|
Efficiency
|
71%
|
78%
|
78%
|
82%
|
|
Adjustable range for DC voltage
|
± 10, -5%
|
± 10%
|
± 10%
|
± 10%
|
|
AC input voltage range
|
85∼ 132VAC/170∼ 264VACselected by switch
|
|
Input current
|
1.3A/115V 0.65A/230V
|
|
AC impulse current
|
Cold-start current 18A/115V 36A/230V
|
|
Leakage current
|
< 0.5mA/240VAC
|
|
Overload protection
|
105%∼ 150%TypeTOLDBACK Reset: auto recovery
|
|
Over-voltage protection
|
|
|
High-temperature protection
|
|
|
Temperature coefficient
|
± 0.03%(0∼ 50)
|
|
Setup rise hold up time
|
200ms, 100ms, 30ms
|
|
Vibration
|
10∼ 500Hz, 2.10min. /1cycle, Period for 60min, Each axes
|
|
Withstand voltage
|
Input and output interval1.5KVAC, Input and enclosure1.5KVAC, Output and enclosure0.5KVAC
|
|
Isolation resistance
|
Input and output interval, Input and enclosure, Output and enclosure0500VAC/100M Ohms
|
|
Working temperature and humidity
|
-10∼ +60, 20%∼ 90%RH
|
|
Store temperature and humidity
|
-20∼ +85, 10%∼ 95RH
|
|
Overall dimension
|
159*97*38mm
|
|
Weight
|
0.5Kgs
|
|
Safety standards
|
Meet UL1012
|
|
EMC standards
|
|
|
Note: 1. The testing condition for the parameter above is: 230VAC input, rated load, 25 70%Rh, Humidity
2. Error, include the setting error, line stability and load stability. (Note: 5)
3. Wave test: adoptingA12double wire for 20MHz, and 0.1uF& uF capacitor short-circuit for interrupting
4. Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.
5. Load stability test: The load is from 0% to 100%, others 60%.
6. C2311must be knocked down.
|